1st Floor Ste
|
Industrial
|
813,360 SF
|
Rate Upon Request
|
|
Clear Height: 36’-40’ measured at the first column line
Drive-In Truck Doors: 12’ x 14’ (insulated)
Truck Doors: 9’ x 10’ (insulated), manual vertical lift
Bay Spacing: 50’ x 54’ typical bay spacing (60’ at speed bay)
Guard Door: “z” guard door track protection at each door
Tilt-up Walls: Concrete tilt-up walls (4,500 psi concrete, type V cement and W/C ratio of 0.45 max), steel truss roof structure with wood deck (Type III-B construction)
Interior Walls: Interior wall painted white and columns with safety yellow 10’ AFF
Skylights: 2% minimum
Roofing: Metal Roof Deck - 60 mil TPO single-ply membrane
Foundation: Slab on Grade 7” over 5” Type II structural, 4,000 psi floors, 4,500 psi walls and foundations
Power: Two 4,000 amp electrical services of 277/480 volt 3-phase power totaling 8,000 amps
Sprinklers: ESFR, automatic fire prevention system
-
Date available: TBD
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: New
|
|
1st Floor Ste
|
Industrial
|
474,934 SF
|
Rate Upon Request
|
|
Divisible: ±237,467 SF
Office: ±3,030 SF
Clear Height: 36’
Drive-In Truck Doors: Eight (8) 12’ x 14’ (insulated)
Truck Doors: Sixty-four (64) 9’ x 10’ (insulated), manual vertical lift
Bay Spacing: 50’ x 54’ typical bay spacing (60’ at speed bay)
Guard Door: “z” guard door track protection at each door
Tilt-up Walls: Concrete tilt-up walls (4,500 psi concrete, type V cement and W/C ratio of 0.45 max), steel truss roof structure with wood deck (Type III-B construction)
Interior Walls: Interior wall painted white and columns with safety yellow 10’ AFF
Skylights: 2% minimum
Roofing: Metal Roof Deck - 60 mil TPO single-ply membrane
Foundation: Slab on Grade 7” over 5” Type II structural, 4,000 PSI floors, 4,500 PSI walls and foundations
Power: Two 4,000 amp electrical services of 277/480 volt 3-phase power totaling 8,000 amps
Sprinklers: ESFR, automatic fire prevention system
Lighting: LED Lighting
Parking: 228 spaces
Trailer Parking: 41 spaces
-
Date available: Now
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: Relet
|
|
1st Floor Ste
|
Industrial
|
274,040 SF
|
Rate Upon Request
|
|
Clear Height: 36’-40’ measured at the first column line
Drive-In Truck Doors: 12’ x 14’ (insulated)
Truck Doors: 9’ x 10’ (insulated), manual vertical lift
Bay Spacing: 50’ x 54’ typical bay spacing (60’ at speed bay)
Guard Door: “z” guard door track protection at each door
Tilt-up Walls: Concrete tilt-up walls (4,500 psi concrete, type V cement and W/C ratio of 0.45 max), steel truss roof structure with wood deck (Type III-B construction)
Interior Walls: Interior wall painted white and columns with safety yellow 10’ AFF
Skylights: 2% minimum
Roofing: Metal Roof Deck - 60 mil TPO single-ply membrane
Foundation: Slab on Grade 7” over 5” Type II structural, 4,000 psi floors, 4,500 psi walls and foundations
Power: Two 4,000 amp electrical services of 277/480 volt 3-phase power totaling 8,000 amps
Sprinklers: ESFR, automatic fire prevention system
-
Date available: TBD
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: New
|
|
1st Floor Ste
|
Industrial
|
257,920 SF
|
Rate Upon Request
|
|
Clear Height: 36’-40’ measured at the first column line
Drive-In Truck Doors: 12’ x 14’ (insulated)
Truck Doors: 9’ x 10’ (insulated), manual vertical lift
Bay Spacing: 50’ x 54’ typical bay spacing (60’ at speed bay)
Guard Door: “z” guard door track protection at each door
Tilt-up Walls: Concrete tilt-up walls (4,500 psi concrete, type V cement and W/C ratio of 0.45 max), steel truss roof structure with wood deck (Type III-B construction)
Interior Walls: Interior wall painted white and columns with safety yellow 10’ AFF
Skylights: 2% minimum
Roofing: Metal Roof Deck - 60 mil TPO single-ply membrane
Foundation: Slab on Grade 7” over 5” Type II structural, 4,000 psi floors, 4,500 psi walls and foundations
Power: Two 4,000 amp electrical services of 277/480 volt 3-phase power totaling 8,000 amps
Sprinklers: ESFR, automatic fire prevention system
-
Date available: TBD
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: New
|
|
1st Floor Ste
|
Industrial
|
329,280 SF
|
Rate Upon Request
|
|
Clear Height: 36’-40’ measured at the first column line
Drive-In Truck Doors: 12’ x 14’ (insulated)
Truck Doors: 9’ x 10’ (insulated), manual vertical lift
Bay Spacing: 50’ x 54’ typical bay spacing (60’ at speed bay)
Guard Door: “z” guard door track protection at each door
Tilt-up Walls: Concrete tilt-up walls (4,500 psi concrete, type V cement and W/C ratio of 0.45 max), steel truss roof structure with wood deck (Type III-B construction)
Interior Walls: Interior wall painted white and columns with safety yellow 10’ AFF
Skylights: 2% minimum
Roofing: Metal Roof Deck - 60 mil TPO single-ply membrane
Foundation: Slab on Grade 7” over 5” Type II structural, 4,000 psi floors, 4,500 psi walls and foundations
Power: Two 4,000 amp electrical services of 277/480 volt 3-phase power totaling 8,000 amps
Sprinklers: ESFR, automatic fire prevention system
-
Date available: TBD
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: New
|
|
1st Floor Ste
|
Industrial
|
1,050,560 SF
|
Rate Upon Request
|
|
-
Date available: TBD
-
Lease term: Negotiable
-
Service type: To Be Determined
-
Space Type: New
|